Pulsarlube EX is a battery operated, single point lubricator with a replaceable 4.5V battery pack.
The EX lubricator includes a powerful positive displacement pump designed to reliably lubricate your equipment. To install, simply mount the EX unit directly on the lubrication point, or remote install up to 10ft. The EX intermittently injects grease via a microprocessor chip to keep your rotating equipment precisely lubricated 24 hrs / day.
PULASRLUBE EX 125cc(EX125)
PULASRLUBE EX 250cc(EX250)
The Pulsarlube EX design has been tested by the UL labs and meet the following requirements:
UL79, Power-Operated pumps for Petroleum dispensing products, Eighth Edition ANSI/ISA-12.12.01-2000, Nonincendive Electrical equipment for use in Class I and II, Division 2 and Class III,
Divisions 1 and 2 Hazardous locations.

Rating Description
CLASS I Flammable Gases, Vapors or Liquids
2 Groups-C, D
DIVISION 2 Where ignitable concentrations of flammable gases, vapors and liquids are not likely to exist under normal operating conditions.
GROUPS - C & D C (Ethylene), D (Propane)
2 Groups-C, D

Operating Temperature Ranges Standard Battery 14¡Æ F ~ 122¡Æ F (-10¡Æ C~50¡Æ C)
Lithium Battery -40¡ÆF~140¡ÆF (-40¡ÆC~+60¡ÆC)
Max Operating Pressure 200psi (15 kg/cm©÷)
Installation Thread 3/8" NPT Adapter (available)
Remote Installation Up to 10 feet (3 meters)
Applications Single point lubrication
Variable Timer Variable Timer

Automatic Locking System:
The Microprocessor locks the LCD within 30 seconds after having been programmed. A "Non - blinking lock I-Con is visible when the LCD is in "Lock - Mode". To unlock the LCD, press the "mode" button for 2 seconds until lock icon disappears.

Warning
-


EXPLOSION HAZARD - DO NOT REMOVE OR REPLACE BATTERIES UNLESS UNIT HAS BEEN TURNED "OFF" BY PRESSING THE POWER BUTTON FOR 2 SECONDS, OR UNLESS AREA IS KNOW TO BE FREE OF IGNITABLE CONCENTRATIONS OF FLAMMABLE GASES OR VAPORS


- IEC 60079-15 Electrical apparatus for explosive gas atmospheres
- IEC 60529 Degrees of protection provided by enclosures
- EN 50021/1999 Electrical apparatus for potentially explosion atmospheres type of protection "n"
- UL 79 Power - Operated pumps for petroleum dispensing products.
- ANSI/ISA-12.12.01-2000 Nonincendive electrical
Equipment for use in class l and ll, Division 2 and class lll, Divisions 1 and 2 hazardous locations.


Certification UL ATEX KTL Remark
Rating Class¥°Division 2 Groups-C, D EEx nL ¥±B T5 IP54 Ex nC ¥±B T5 IP54 -
Gas groups D-C1 I Div 1/2 ¥±A ¥±A Propane Typical Gas
D-C1 I Div 1/2 ¥±B ¥±B Ethylene
Maximum Surface Temperature T6(85¡É) T5(100¡É) T5(100¡É) The skin temperature shall not exceed the minimum ignition temperature of the substances to be found in the hazardous location. The "T" code designations apply to motors and other types of electrical equipment subject to hazardous location classification.
Enclosure protection indices - IP54 IP54 Protection against dust; -IP5X
Dust penetration is not prevented altogether, but dust must not enter in sufficient quantities to prevent the equipment from operating satisfactorily, or to impair safety.
Protection against water spray;-IPX4
Water splashes on to the enclosure from any direction must not have any harmful effects.
Classification of hazardous locations CI¥°Div2 CI¥°Zone2(gas) Zone2(gas) Zone22(dust) - Ignitable concentrations not likely to exist under normal operations, or may exist for a short time only
Certificate number E304815 - 2007-1167-Q1  