Home |Products | Pulsarlube EX |
|
|
The Pulsarlube EX design has been tested by the UL labs and meet the following requirements:
UL79, Power-Operated pumps for Petroleum dispensing products, Eighth Edition
ANSI/ISA-12.12.01-2000, Nonincendive Electrical equipment for use in Class I and
II, Division 2 and Class III, Divisions 1 and 2 Hazardous locations.
|
| Rating |
Description |
| CLASS I |
Flammable Gases, Vapors or Liquids
2 Groups-C, D |
| DIVISION 2 |
Where ignitable concentrations of flammable gases, vapors and liquids are not likely to exist under normal operating conditions. |
| GROUPS - C & D |
C (Ethylene), D (Propane)
2 Groups-C, D |
| Operating Temperature Ranges |
Standard Battery |
14¡Æ F ~ 122¡Æ F (-10¡Æ C~50¡Æ C) |
| Lithium Battery |
-40¡ÆF~140¡ÆF (-40¡ÆC~+60¡ÆC) |
| Max Operating Pressure |
200psi (15 kg/cm©÷) |
| Installation Thread |
3/8" NPT Adapter (available) |
| Remote Installation |
Up to 10 feet (3 meters) |
| Applications |
Single point lubrication |
| Variable Timer |
Variable Timer |
| Automatic Locking System: |
| The Microprocessor locks the LCD within 30 seconds after having been programmed. A "Non - blinking lock I-Con is visible when the LCD
is in "Lock - Mode". To unlock the LCD, press the "mode" button for 2 seconds until lock icon disappears.
|
Warning |
-
|
EXPLOSION HAZARD - DO NOT REMOVE OR REPLACE BATTERIES UNLESS UNIT HAS BEEN TURNED "OFF" BY
PRESSING THE POWER BUTTON FOR 2 SECONDS, OR UNLESS AREA IS KNOW TO BE FREE OF IGNITABLE
CONCENTRATIONS OF FLAMMABLE GASES OR VAPORS
|
| - IEC 60079-15 |
Electrical apparatus for explosive gas atmospheres
|
|
| - IEC 60529 |
Degrees of protection provided by enclosures
|
|
| - EN 50021/1999 |
Electrical apparatus for potentially explosion atmospheres type of protection "n"
|
|
| - UL 79 |
Power - Operated pumps for petroleum dispensing products.
|
|
| - ANSI/ISA-12.12.01-2000 |
Nonincendive electrical
Equipment for use in class l and ll, Division 2 and class lll, Divisions 1 and 2 hazardous locations.
|
| Certification |
UL |
ATEX |
KTL |
Remark |
| Rating |
Class¥°Division 2 Groups-C, D |
EEx nL ¥±B T5 IP54 |
Ex nC ¥±B T5 IP54 |
- |
| Gas groups |
D-C1 I Div 1/2 |
¥±A |
¥±A |
Propane |
Typical Gas |
| D-C1 I Div 1/2 |
¥±B |
¥±B |
Ethylene |
| Maximum Surface Temperature |
T6(85¡É) |
T5(100¡É) |
T5(100¡É) |
The skin temperature shall not exceed the minimum ignition temperature of the substances to be found in the hazardous location. The "T" code designations apply to motors and other types of electrical equipment subject to hazardous location classification. |
| Enclosure protection indices |
- |
IP54 |
IP54 |
Protection against dust; -IP5X
Dust penetration is not prevented altogether, but dust must not enter in sufficient quantities to prevent the equipment from operating satisfactorily, or to impair safety.
Protection against water spray;-IPX4
Water splashes on to the enclosure from any direction must not have any harmful effects.
|
| Classification of hazardous locations |
CI¥°Div2 CI¥°Zone2(gas)
|
Zone2(gas) Zone22(dust)
|
- |
Ignitable concentrations not likely to exist under normal operations, or may exist for a short time only |
| Certificate number |
E304815 |
- |
2007-1167-Q1 |
|
 |
|
|
|
|
|
|
|