Welcome to Pulsarlube USA, inc
¤ý The MS unit turns "On" or "Off" in synchronization with the equipment on which it is installed. It will dispense the preset amount of grease as long as the machine is operating. If the equipment is not operating, then the Pulsar lube MS unit goes into "stand-by mode" and does not dispense lubrication until the machine operates again.
The MS unit is not an externally powered unit. It operates on it's own battery. Battery should be replaced simultaneously with grease pouch. The MS unit will turn ON/OFF through a Relay Box in accordance with the related equipment power signal


Item Description
Replaceable 125, 250, or 500cc Grease pouch 125cc, 250cc or 500cc(ML500, OL500)
High operating pressure 20Kgf/§²(280psi)
Wide operating temp range -15¡É ~ 60¡É (5¢ªF ~ 140¢ªF)
Multipoint Lubrication Up to 8 points
Power DC 4.5V Replaceable Alkaline Battery
Other specification Same as Pulsarlube M
Note : Technical information is subject to change without notice


Item Description
Rate Input AC 100~440V, 0.5W50 ~ 60Hz
Rate Output Signal(Open collector Type)
LED Lamp to indicate power ON Red LED
Case size(mm) 85(D) x 49(W) x 32(H)
Wire Length Power Supply Side Input 1M
Output 4.5M
MS Side 90mm
Remark) MS Relay Box was designed to fit Pulsarlube MS unit. Warranty will be void if unspecified adapter or converter were being used.

MS working process
MS unit time control (Example; 1 Month Mode)
1. If MS unit was set 1 Month Mode, then start "1" month blinking and 30 days displayed on LCD.
2. If MS unit was working with main machine for 10days, then "1" month blinking and 20 days displayed on LCD
3. Main machine was power OFF for 10 days, and then MS unit has been sleep mode for 10 days. No LCD display.However, CPU will keep internal data using back up battery power.
4. Now, Main machine power ON, MS unit will be on and continue working for the remaining 20 days
5. After 40 days (30days working, 10 days sleeping), LCD, Red LED Signal Lamp will be blinking.
6. Replace grease pouch only. (No need to change battery even though Low Battery I-con appear on the LCD)
7. After replacing grease pouch, Press "RESET " button, press "POWER" button and set "MODE"
Remark:¤ýRate input power for MS unit is DC 5.0 Voltage.
             ¤ýMS unit can be stopped by pressing "POWER" button
             ¤ýIf main machine power OFF, then MS unit OFF after 6~7seconds and
              all system will be in the sleep mode.
             ¤ýInitially, MODE has to set when main machine power ON


1. Please install unit at convenient location to replace grease pouch and control unit.
2. Direct or remote mount unit to the bearing as you would a Pulsarlube M unit
3. Connect female end on Relay Box to the MS unit main body
4. Connect Relay Box to machines' power cable
5. No need to check wire (+),(-) polarity for AC power source
6. All safety and operating instructions should be read before using Relay Box
1) Read instructions. All safety and operating instructions should be read before using Relay Box and should be retained for future reference.
2) Water and Moisture. The Relay Box should never be used in, on or near water due to the risk of fatal shock.
3) Heat. Never locate the Relay Box near heat sources such as a radiator, floor register, stove or other heat-generating device.
4) Dangerous Entry. Care should be taken that no foreign objects or liquids fall or are spilled inside the Relay Box
5) Ventilation. The Relay Box should always be located in such as way that it maintains proper ventilation.
6) Flammable. Keep away from flammable and combustible materials.
7) Vibration. Keep away from vibration prone items, machine and equipments.
8) Service. The user should not attempt to service the Relay Box beyond what is described in the user's manual. All other servicing should be referred to qualified personnel.
7. Connect MS unit with Relay Box (Please check red LED lamp is ON)
8. Turn ON POWER button and setting MODE.
Wiring
1. Relay Box can connect directly with power cable.
2. MC (Magnet Coil) Terminal of main machine power source
3. Main machine power control switch ON lamp Terminal which is on the control panel case front
4. Relay Terminal
5. PLC Terminal
6. Other Terminal
Pulsarlube USA, Inc
4312 DIPAOLO CENTER. GLENVIEW, IL 60025 TEL : 847-795-0591 FAX : 847-795-0119