¤ý The MSP unit turns "On" or "Off" in synchronization with the machine on which it is installed. It will dispense the preset amount of grease as long as the machine is operating. If the machine is not operating, then the Pulsarlube MSP unit goes into "stand-by mode" and does not dispense lubrication until the machine operates again.
The MSP is an externally powered unit. The power supply connected to the machine or PLC operates unit. Therefore, there is no need to replace battery. Only grease pouch will be replaced.


Item Description
Available Model KLT125, KLT250, ML500 and OL500
Operating Pressure 20kgf/§²(280psi)
Operating Temperature -15¡É ~ 60¡É (5¢ªF ~ 140¢ªF)
Multi Points Up to 8 points
Back Up Battery DC 4.5V(Service Life 5 years),
No need replacement along with grease pouch
Power Supplier Select power supply according to machine power
Source VAC Adaptor for AC power,
VDC converter for DC power
Other Specification Same as Pulsarlube M


Item MSP VAC
AC- DC Adapter
MSP VDC
DC- DC Converter
Rate Input Power 100~220V, 50 ~ 60Hz 12V ~ 24V
Rate Output Power 5.0V, 2A 5.0V, 2A
LED Lamp to indicate power ON RED LED RED LED
Case Size(mm) 85(D) x 49(W) x 32(H) 85(D) x 49(W) x 32(H)
Wire Length Power
Supply
Side
Input 1M 1M
Output 4.5M 4.5M
MSP 90mm 90mm
Remark) Power supply VAC Adaptor and VDC Converter were designed to fit Pulsarlube MSP unit. Warranty will be void if unspecified adapter or converter were being used.

MSP working process
MSP unit time control (Example; 1 Month Mode)
1. If MSP unit was set 1 Month Mode, then start "1" month blinking and 30 days displayed on LCD
2. If MSP unit was working with main machine for 10days, then "1" month blinking and 20 days displayed on LCD
3. Main machine was power OFF for 10 days, and then MSP unit has been sleep mode for 10 days. No LCD display.However, CPU will keep internal data using back up battery power.
4. Now, Main machine power ON, MSP unit will be on and continue working for the remaining 20 days
5. After 40 days (30days working, 10 days sleeping), LCD, Red LED Signal Lamp will be blinking.
6. Replace grease pouch only. (No need to change battery even though Low Battery I-con appear on the LCD)
7. After replacing grease pouch, Press "RESET " button, press "POWER" button and set "MODE"
Remark:¤ýRate input power for MSP unit is DC 5.0 Voltage.
             ¤ýMSP unit can be stopped by pressing "POWER" button
             ¤ýIf main machine power OFF, then MSP unit OFF after 6~7seconds and
                  all system will be in the sleep mode.
             ¤ýInitially, MODE has to set when main machine power ON


1. If MS unit was set 1 Month Mode, then start "1" month blinking and 30 days displayed on LCD.
2. If MS unit was working with main machine for 10days, then "1" month blinking and 20 days displayed on LCD
3. Main machine was power OFF for 10 days, and then MS unit has been sleep mode for 10 days. No LCD display.However, CPU will keep internal data using back up battery power.
4. Now, Main machine power ON, MS unit will be on and continue working for the remaining 20 days
5. After 40 days (30days working, 10 days sleeping), LCD, Red LED Signal Lamp will be blinking.
6. Replace grease pouch only. (No need to change battery even though Low Battery I-con appear on the LCD)
7. After replacing grease pouch, Press "RESET " button, press "POWER" button and set "MODE"
Remark:¤ýRate input power for MS unit is DC 5.0 Voltage.
             ¤ýMS unit can be stopped by pressing "POWER" button
             ¤ýIf main machine power OFF, then MS unit OFF after 6~7seconds and
              all system will be in the sleep mode.
             ¤ýInitially, MODE has to set when main machine power ON


1. Please install unit at convenient location to replace grease pouch and control unit.
2. Direct or remote mount unit to the bearing as you would a Pulsarlube M unit
3. Connect female end on Power supply to the MSP unit main body
4. Connect Power Supply to machines' power source
5. Have to select Power Supply VDC or VAC depending on main machine power source AC or DC
6. No need to check wire (+),(-) polarity for AC power source
7. Have to check (+), (-) polarity in case of DC power source
VDC power supply wire; (+) Light Blue color, (-) Brown color wire.
8. All safety and operating instructions should be read before using VAC / VDC power supplies
1) Read instructions. All safety and operating instructions should be read before using AC/DC adapter and should be retained for future reference.
2) Water and Moisture. The power supply should never be used in, on or near water due to the risk of fatal shock.
3) Heat. Never locate the power supply near heat sources such as a radiator, floor register, stove or other heat-generating device.
4) Dangerous Entry. Care should be taken that no foreign objects or liquids fall or are spilled inside the power supply.
5) Ventilation. The power supply should always be located in such as way that it maintains proper ventilation.
6) Flammable. Keep away from flammable and combustible materials.
7) Vibration. Keep away from vibration prone items, machine and equipments.
8) Service. The user should not attempt to service the power supply beyond what is described in the user's manual. All other servicing should be referred to qualified personnel.
9. Connect MSP unit with power supply VAC or VDC (Please check red LED lamp is ON)
10. Turn ON POWER button and setting MODE.
Wiring
VAC Adapter VDC Converter
- MC (Magnet Coil) Terminal of main machine
   power source
- Main machine power control switch ON lamp
   Terminal which is on the control panel case front
- Relay Terminal
- PLC Terminal
- Other Terminal
- DC 12~24 Volt out put Terminal
Don't connect MSP unit directly to Electric Motor or Electric Power cable.